Journal article

Photovoltaic (PV) performance modelling in the absence of onsite measured plane of array irradiance (POA) and module temperature

Journal
Roofs Solar energy Building performance Energy modelling Sydney
Description

In this study, the outputs from a simple PV performance model were compared to measurements of AC power for three PV systems located across Sydney, Australia. The study aimed to investigate the level of uncertainty and bias of the model when onsite measurements of plane of array (POA) irradiance and module temperature were not available. The results demonstrated that the simple PV performance model estimated the AC performance with a low level of model bias (NBME=±3.2%) and uncertainty (NRMSE

For module temperature, the results indicated that the choice of model coefficients had a significant impact on the performance of the module temperature models. In particular, for the three parallel roof mounted PV systems studied, the results suggested that the open rack/free standing or well ventilated module temperature coefficients should be used within the module temperature models investigated. This selection of coefficients was not directly evident given the PV systems investigated were parallel roof mounted PV systems, not free standing rack mounted arrays.

Publication Details
Volume:
86
DOI:

10.1016/j.renene.2015.09.005

Duration:
2016
Pagination:
760-769