Sorry, you need to enable JavaScript to visit this website.

Housing

Alternative labels
Residential building
Dwellings
Housing strategy
Subject Hierarchy
Permalinks
APO URI

ADVERTISEMENT

Conference paper

Domestic energy use by Australians with Multiple Sclerosis


Heat intolerance is a major medical problem affecting people with multiple sclerosis (MS). When their core body temperatures increase people with MS experience significantly increased symptoms which greatly reduces their capacity to participate in social, household and work activities, as well as increasing their need for pharmaceuticals and medical services. For people with MS, using...
Conference paper

Effects of UV on radiation properties of cool coating


Purpose / Context - Cool coating is a passive technique for reducing the solar heat gain and cooling energy consumption of buildings. However the radiation properties (i.e., solar reflectance and thermal emittance) of cool coating would be changed, usually adversely, during its ageing process, and its thermal performance would be degraded accordingly. UV could cause...
Conference paper

Rational or emotional? Failing to attract home owners in Germany to conduct energy-efficient renovation measures from a marketing perspective


Purpose / Context – Energy efficiency measures/ private home-owners/ decision process Methodology / Approach –Explorative research/ qualitative interviews/ content analysis Results – Decisions towards energetic renovation measures can be characterized as a strategic consumer decision rather than the often assumed purely investment decision. Emotionally shaped motives seem to displace rational determinants such as financial savings...
Conference paper

The regulating effect of S.trifasciatavar.laurentii on indoor environment


The purpose of this paper is to study the effect of S.trifasciatavar.laurentii (variegated snake plant) on indoor environment. The results showed experimental room with three pots of S.trifasciatavar.laurentii was 1.6% higher in the room air relative humidity, 0.997℃ lower in temperature, 15.5% lower in PM2.5 concen-tration, 16.4% lower in PM10 concentration than the control room.
Conference paper

Pilot monitoring of ultrafine particle number concentrations in some households in Hanoi


Purpose / Context - Epidemiological studies have consistently shown that fine and course airborne particles (PM2.5 and PM10), as well as ultrafine (UF) particles measured in terms of particle number (PN) concentrations, are toxic to human health. A number of studies on particle concentrations in households were conducted worldwide; however, no such studies have so...